Testing

Magboard is the most heavily tested MgO board on the market with performance results that are truly impressive.
  • Intertek Listed as Non Combustible.
  • Thoroughly tested for numerous applications and assemblies.
  • Outperforms most sheathing products with a single 1/2" board.
  • Exceeds building code requirements in common commercial or residential construction.


Test and Preformance Requirements Test Standard Requirements Test Results
Flexural Strength ASTM C1185 min 580 psi both wet and dry Dry parallel 1576 psi, dry perpendicular 2251 psi, wet parallel 1291 psi, wet perpendicular 2041 psi
Freeze Thaw Cycling ASTM C666 No disintegration after 25 Cycles Pass
Dimension and Tolerance ASTM C1186 Pass
Moisture Movement ASTM C1185-08 Accepted dimensional tolerance from 30 to 90% humidity 0.02%
Water Absorption ASTM E96 29.80%
Water Vapour transmission ASTM E96-E96M/05 2.46 perms
Compression Indentation ASTM D2394 >1250 psi < .05 inch Pass 1736 PSI
Nail Head Pull Through ASTM D1037 125 lbf 292 lbf - pass
Lateral Nail Resistance ASTM D1037 125 lbf Pass dry 1/4" 115 lb, wet 1/4" 41lb, dry 3/8" 196lb, wet 3/8" 113 lb, dry 1/2" 261lb, wet 1/2" 157lb, dry 3/4" 337 lb, wet 3/4" 209lb
Falling Ball Impact ASTM D1037 no damage at 12" drop Pass
Shear Bond Strength Dry Portland Cement ANSI A 118.1 50 PSI at 7 day curing 53.7
Latex Portland Cement Mortar ANSI A 118.4 50 PSI at 7 day curing 58.64
Humidified Deflection ASTM C1396 Pass as Ceiling Board max 5/16" or as ceiling finish .0639" Pass as ceiling board and finish .053"
Fungus Testing ASTM D3273 Pass No evidence of fungal growth rating of 10
Surface Burning Characteristics ASTM E84 5 smoke 10 flame contribution 0 smoke 0 flame contribution
Use as Structural floor Sheathing ASTM AC367 Heavy duty application
Use as Wall Sheathing or floor Underlayment ASTM AC376 Heavy duty application
Use as substrate in interior areas ASTM AC378 Heavy duty application
Structural 2x6 wood frame 3.5 in steel frame and Structural Insulated Panel configurations ASTM C 297, ASTM C273, ASTM C393, ASTM C481, ASTM E72 Transverse, Axial, Flexural, Racking Shear tests In excess of code requirements
Fire resistance rated construction ASTM E119 2 hour rating on steel or wood assembly as per Magboard assembly instructions
Non combustible construction ASTM E136 pass or exceed
Quality Control Manufactured under approved QC program with inspections by an IAS (International Accreditation Service) accredited inspection agency Intertek Certified

There Is Only One Magboard

The tests below were performed by Intertek and NTA, Inc. according to ASTM standards and protocols. Most of the tests were done on 4x8 sheets of 12mm (1/2”) Magboard.